Calibrating Moisture Sensor
Calibrating Moisture Sensor
- On Display
-
- Wait for a segment of the pass where the moisture value is stable.
- When stable, note the moisture value.
- On Combine
-
- 2 seconds after noting the moisture value - pull a grain sample of what is coming from the bubble auger
- Test sample in a reliable moisture tester
- Calculate difference between what was read on the display and what was read by the moisture tester
- On Display
- Setup > Systems > Moisture Gain > Enter the difference as the offset
- Save > Equip > Save and Load > Update Combine
Additional info:
While you are going through the field, make sure it's stable and moisture isn't jumping around. If Monitor reads different from moisture test, put in difference. Example: Monitor reads 16, moisture test reads 15, insert -1.
Back to YieldSense Operations