Calibrating Moisture Sensor

 
 
  • On Display 
    • Wait for a segment of the pass where the moisture value is stable.
    • When stable, note the moisture value.
  • On Combine
    • 2 seconds after noting the moisture value - pull a grain sample of what is coming from the bubble auger
    • Test sample in a reliable moisture tester
    • Calculate difference between what was read on the display and what was read by the moisture tester  
  • On Display
    • Setup > Systems > Moisture Gain > Enter the difference as the offset 
    • Save > Equip > Save and Load > Update Combine

Additional info:

While you are going through the field, make sure it's stable and moisture isn't jumping around. If Monitor reads different from moisture test, put in difference. Example: Monitor reads 16, moisture test reads 15, insert -1.